面向医学影像的负责任量子机器学习:跨敏感子群的公平性审计
Responsible Quantum Machine Learning for Medical Imaging: A Fairness Audit Across Sensitive Subgroups
Giovanni dos Santos Franco · Felipe Mahlow · Ellison Fernando Cardoso · Jos\'e Adenaldo Santos Bittencourt · Felipe Fanchini
中文摘要
量子机器学习(QML)在医学分类中日益受到探索,但其在子群感知公平性标准下的表现仍缺乏研究。假设QML并非天然公平,对医学影像的经典与量子分类器进行实证公平性审计。评估两个场景:DDI上的皮肤病变(敏感属性:Fitzpatrick皮肤类型)和CheXpert衍生数据上的胸部X光(敏感属性:年龄组)。使用ResNet-18嵌入,在基线和三种缓解设置下训练SVM、MLP、QSVM和QCNN:可微均衡赔率(EO)正则化、梯度反转学习(GRL)及两者结合。基础模型(PanDerm、EVA-X)作为外部参考。量子分类器可能达到有竞争力的总体性能,但仍表现出子群差异。由于较小的子群AUC差距可能源于降低最佳组而非改善最差组,每种缓解还针对相对于其基线的预设非劣效性边界进行测试。在此标准下,若干差异最小的配置,尤其是DDI上带GRL的QCNN,因全局判别力损失而不具临床可接受性。在DDI上,带GRL+EO的QSVM表现最佳,在性能/公平性权衡上接近PanDerm;在CheXpert上,带GRL的QCNN达到最高总体性能但差异增加,EVA-X仍更强。公平性效应依赖于模型和数据集,因此QML需要实证的子群感知评估。所有量子模型在经典模拟中运行;不声称量子优势。
关键要点
- 01量子机器学习在医学影像中的子群公平性尚未被充分研究,本文进行实证审计。
- 02在DDI和CheXpert上比较SVM、MLP、QSVM、QCNN及EO、GRL缓解策略。
- 03差异最小的配置可能因全局判别力下降而不具临床可接受性。
- 04公平性效应依赖模型与数据集,QML需子群感知评估,且无量子优势。
解读
尚无解读。
原始英文摘要
arXiv:2610.37819v1 Announce Type: cross Abstract: Quantum machine learning (QML) is increasingly explored for medical classification, yet its behaviour under subgroup-aware fairness criteria remains understudied. We present an empirical fairness audit of classical and quantum classifiers for medical imaging, assuming QML is not inherently fair. Two scenarios are evaluated: dermatological lesions on DDI (sensitive attribute: Fitzpatrick skin type) and chest X-rays on CheXpert-derived data (sensitive attribute: age group). Using ResNet-18 embeddings, we train SVM, MLP, QSVM and QCNN under a baseline and three mitigation settings: differentiable Equalized Odds (EO) regularisation, Gradient Reversal Learning (GRL), and both combined. Foundation models (PanDerm, EVA-X) serve as external references. Quantum classifiers may achieve competitive aggregate performance while still exhibiting subgroup disparities. Since a smaller subgroup AUC gap may stem from degrading the best group rather than improving the worst, each mitigation is also tested against a pre-specified non-inferiority margin relative to its baseline. Under this criterion, several configurations with the smallest disparity, notably QCNN with GRL on DDI, are not clinically acceptable due to loss of global discrimination. On DDI, QSVM with GRL+EO performed best and approached PanDerm in the performance/fairness trade-off; on CheXpert, QCNN with GRL achieved the highest aggregate performance but increased disparity, and EVA-X remained stronger. Fairness effects are model- and dataset-dependent, so QML requires empirical subgroup-aware evaluation. All quantum models run in classical simulation; we claim no quantum advantage.